banner

Products

product

Syringe Infusion Pump

Syrion Plus

  • Running Program Changing the infusion Rate without Stopping the Infusion
  • ‘Green’ Light indicator is flashing on the top of pump When Pump is Running Mode
  • Standby mode facility available
  • Last Running program continue facility
  • Stackable up to 5 Syringe Pump (optional)
  • Front loading with Auto & manual plunger opening syringe pump
  • Dual Switch Master (Mechanical) And Slave (Touch) For ON/OFF (optional)
  • Keypad Lock Facility Available
  • Can be used in ICU, ICCU, Surgery, Ambulance, Pain Management, and also for Thalassemia patients with high precision Accuracy
  • Easy to Fixing with Horizontal and Vertical Pole Using Rotating Clamp (Optional)
  • Easy To Upgradable (optional)
  • Load Default (Automatic) Calibration Available Without Interfacing Any peripheral Device
  • Docking Station (If Required) Dock 5 Pumps & Mountable on Poles with single Power Supply Cord (Optional)

Specifications

Overall Accuracy 2% +/- (measured Time >1 Hr; Min 0.2ml)
Applicable Syringe 2/3ml, 5/6ml, 10/12ml, 20/25ml, 50/60ml
Mode Flow Rate, Target Time, Sequential Mode Tapper Up/Down, Weight Mode, PCA (Patient-controlled analgesia) (Optional)
Syringe Type Used B BRAUN-Omnifix, B BRAUN-Perfuser, BD-Pressie, BD-Luerlok, BD-Discardit, BD-Plastipak, BD-Emerald, Dispowan, Romson, Nipro & Custom Programmable for Any Brand of Syringe. 2/3, 5/6, 10/12, 20/25, 50/60 ML Syringes with Their Different Models.
Flow Rate Range 0.01 - 100ml/hr For 2/3 ML Syringe
0.1 - 200ml/hr For 5/6 ML Syringe
0.1 - 500ml/hr For 10/12 ML Syringe
0.1 - 800ml/hr For 20/25 ML Syringe
0.1 - 2000ml/hr For 50/60 ML Syringe
Infusion Volume Limit 9999ml, Programmable Every 0.1ml
Auto Detection Automatic Syringe size detection of 2, 5, 10, 20, 50 ml
Drug Library 50 Number of Different Drugs
Bolus Purge Bolus & Auto Bolus
Purge Bolus Flow Rate 300ml/hr For 2/3 ML Syringe
300ml/hr For 5/6 ML Syringe
500ml/hr For 10/12 ML Syringe
800ml/hr For 20/25 ML Syringe
1500ml/hr For 50/60 ML Syringe
Auto Bolus Flow Rate 0.1 to 200ml/hr For 2/3 ML Syringe (Programmable Rate Set)
0.1 to 300ml/hr For 5/6 ML Syringe (Programmable Rate Set)
0.1 to 500ml/hr For 10/12 ML Syringe (Programmable Rate Set)
0.1 to 800ml/hr For 20/25 ML Syringe (Programmable Rate Set)
0.1 to 1500ml/hr For 50/60 ML Syringe (Programmable Rate Set)
Occlusion Pressure High Mode, Medium Mode, Low Mode, No Occlusion
Anti-Bolus Function Available, Automatic pressure reduce in Drug delivery line During Occlusion Alarm Occurs
KVO Rate Min 0.1ml/hr to 1% of Selected Infusion Rate upto 5ml/hr (or Manual select)
Audible and Visual Alarms ‘Red’ indicator is flashing on the top of pump when any alarm occurred:
- Connect Power / Low Battery
- Check Syringe / Drive Disengage
- Occlusion – Anti Bolus – KVO Active
- Near END of infusion
- Infusion Completed or End of Infusion
Intimation Insert Syringe
PCA Active (Optional)
Pre Occlusion Detected
Bolus Active / Stand By (Hold)
Display 3.0” Large Graphics display indicates Rate (in big font) Infused Volume, Time remain, Drug Name, Set Volume, Syringe size, Syringe Name, VTBI, graphically presentation of the set occlusion Pressure continuously shown on Display
Power Power Supply Internal: AC Input Range 110 Volt To 280 Volt AC, 50/60Hz
Battery: SMF Rechargeable / Lithium-Iron 7.4V 2000mAh
Battery Charging Time: Lithium – Iron Standard 06 Hr @ 5ml/hr
Battery Operating: Lithium – Iron 6-8Hr @ 5ml/Hr (Optional)
Power Consumption: 10 Watts Max.
Housing and Construction Weight: 1.6 Kg Approx.
Dimension: 215 mm (l), 120 mm (h), 115 mm (w) Approx.
Temperature: 0 to 48°C for Operating / -10 to 60°C for Storage
Humidity: 20 to 75% for Operating / 15 to 100% for Storage
Air Pressure: 50 to 100kPa for Operating / 40 to 110kPa for Storage
Interface RS485 (Optional)
Standard and Test Certification IEC Certification
Quality Standard ISO 13485 : 2016
Fuse Type 220V 2 x 2 Amp

Schedule a Meeting with our

Devay Representative?