Syringe Infusion Pump
| Overall Accuracy | 2% +/- (measured Time >1 Hr; Min 0.2ml) |
| Applicable Syringe | 2/3ml, 5/6ml, 10/12ml, 20/25ml, 50/60ml |
| Mode | Flow Rate, Target Time, Sequential Mode Tapper Up/Down, Weight Mode, PCA (Patient-controlled analgesia) (Optional) |
| Syringe Type Used | B BRAUN-Omnifix, B BRAUN-Perfuser, BD-Pressie, BD-Luerlok, BD-Discardit, BD-Plastipak, BD-Emerald, Dispowan, Romson, Nipro & Custom Programmable for Any Brand of Syringe. 2/3, 5/6, 10/12, 20/25, 50/60 ML Syringes with Their Different Models. |
| Flow Rate Range |
0.01 - 100ml/hr For 2/3 ML Syringe 0.1 - 200ml/hr For 5/6 ML Syringe 0.1 - 500ml/hr For 10/12 ML Syringe 0.1 - 800ml/hr For 20/25 ML Syringe 0.1 - 2000ml/hr For 50/60 ML Syringe |
| Infusion Volume Limit | 9999ml, Programmable Every 0.1ml |
| Auto Detection | Automatic Syringe size detection of 2, 5, 10, 20, 50 ml |
| Drug Library | 50 Number of Different Drugs |
| Bolus | Purge Bolus & Auto Bolus |
| Purge Bolus Flow Rate |
300ml/hr For 2/3 ML Syringe 300ml/hr For 5/6 ML Syringe 500ml/hr For 10/12 ML Syringe 800ml/hr For 20/25 ML Syringe 1500ml/hr For 50/60 ML Syringe |
| Auto Bolus Flow Rate |
0.1 to 200ml/hr For 2/3 ML Syringe (Programmable Rate Set) 0.1 to 300ml/hr For 5/6 ML Syringe (Programmable Rate Set) 0.1 to 500ml/hr For 10/12 ML Syringe (Programmable Rate Set) 0.1 to 800ml/hr For 20/25 ML Syringe (Programmable Rate Set) 0.1 to 1500ml/hr For 50/60 ML Syringe (Programmable Rate Set) |
| Occlusion Pressure | High Mode, Medium Mode, Low Mode, No Occlusion |
| Anti-Bolus Function | Available, Automatic pressure reduce in Drug delivery line During Occlusion Alarm Occurs |
| KVO Rate | Min 0.1ml/hr to 1% of Selected Infusion Rate upto 5ml/hr (or Manual select) |
| Audible and Visual Alarms |
‘Red’ indicator is flashing on the top of pump when any alarm occurred: - Connect Power / Low Battery - Check Syringe / Drive Disengage - Occlusion – Anti Bolus – KVO Active - Near END of infusion - Infusion Completed or End of Infusion |
| Intimation |
Insert Syringe PCA Active (Optional) Pre Occlusion Detected Bolus Active / Stand By (Hold) |
| Display | 3.0” Large Graphics display indicates Rate (in big font) Infused Volume, Time remain, Drug Name, Set Volume, Syringe size, Syringe Name, VTBI, graphically presentation of the set occlusion Pressure continuously shown on Display |
| Power |
Power Supply Internal: AC Input Range 110 Volt To 280 Volt AC, 50/60Hz Battery: SMF Rechargeable / Lithium-Iron 7.4V 2000mAh Battery Charging Time: Lithium – Iron Standard 06 Hr @ 5ml/hr Battery Operating: Lithium – Iron 6-8Hr @ 5ml/Hr (Optional) Power Consumption: 10 Watts Max. |
| Housing and Construction |
Weight: 1.6 Kg Approx. Dimension: 215 mm (l), 120 mm (h), 115 mm (w) Approx. Temperature: 0 to 48°C for Operating / -10 to 60°C for Storage Humidity: 20 to 75% for Operating / 15 to 100% for Storage Air Pressure: 50 to 100kPa for Operating / 40 to 110kPa for Storage |
| Interface | RS485 (Optional) |
| Standard and Test Certification | IEC Certification |
| Quality Standard | ISO 13485 : 2016 |
| Fuse Type | 220V 2 x 2 Amp |